ISonic 2009 – UPA Scope Phased Array Flaw Detector


Product Code: ISonic 2009 UPA Scope – Ultrasonic Phased Array

The Sonotron ISonic 2009 UPA-Scope – Portable High Performance Ultrasonic Phased Array Flaw Detector & Recorder with Conventional UT & TOFD Channels

ISonic 2009 – UPA Scope – Portable Phased Array Ultrasonic Flaw Detector and Recorder

Phased Array Modality
• 64:64 phased array electronics organized as 1 X 64:64 or 2 X 32:32 – independently adjustable emitting and receiving aperture, parallel firing, A/D conversion, and on-the-fly real time digital phasing
• Phased array pulser receiver with image guided ray tracing
• True-To-Geometry and regular B-Scan and Sector Scan (S-Scan) accompanied with all-codes-compliant A-Scan based evaluation
• Unique Tandem-B-Scan for the detection of planar vertically oriented defects
• Built-in automatic coupling monitor and lamination checker for wedged probes
• Multi-group / dual side scanning and imaging with use of one probe
• Encoded / time-based line scanning with Top (C-Scan), Side, End Mapping and 3D Viewing
• Independent gain per focal law adjustment: pure angle gain compensation for S-Scan, etc.
• DAC, TCG 
• Processing of diffracted and mode converted signals for defects sizing and pattern recognition 
• Operating matrix-array probes with real time three-dimensional imaging (3D-Scan)

Conventional UT and TOFD Modalities
• 1, 8, or 16 channels
• Single / dual modes of pulsing/receiving
• Regular A-Scan
• Thickness B-Scan
• True-to-Geometry flaw detection B-Scan – straight / angle beam probes
• CB-Scan
• TOFD
• Strip Chart and Stripped C-Scan
• Parallel or sequential pulsing/receiving and A/D conversion
• DAC, DGS, TCG
• FFT signal analysis 
• 100% raw data capturing
• Powerful off-line data analysis toolkit
• Intuitive User Interface
• Light rugged case
• Sealed keyboard and mouse
• Large 8.5” bright touch screen
• Ethernet and 2 X USB Ports
• Remote control – UT over IP
• Built-in encoder port

ISONIC 2009 UPA Scope uniquely combines phased array, single- and multi-channel conventional UT, and TOFD modalities providing 100% raw data recording and imaging. Along with portability, lightweight, and battery operation this makes it suitable for all kinds of every-day ultrasonic inspections

Phased array modality is performed by powerful 64:64 phased array electronics organized as 1 X 64:64 or 2 X 32:32 with independently adjustable emitting and receiving aperture, each may consist of 1 X 1…64 or 2 X 32:32 elements. Groups of phased array probe elements composing emitting and receiving aperture may be fully or partially matching or totally separated allowing flexible managing of incidence angles, focal distances, types of radiated and received waves including directly reflected and diffracted mode converted signals

Each channel is equipped with it’s own A/D converter. Parallel firing, A/D conversion, and ”on-the-fly” digital phasing are provided for every possible composition and size of the emitting and receiving aperture. Thus implementation of each focal law is completed within single pulsing/receiving cycle providing maximal possible inspection speed.

Depending on configuration ISONIC 2009 UPA Scope carries 1, 8, or 16 additional independent channels for conventional UT and TOFD inspection and recording capable for both single and dual modes of pulsing/receiving

High ultrasonic performance is achieved through firing phased array, TOFD, and conventional probes with bipolar square wave initial pulse with wide-range-tunable duration and amplitude. Maximal amplitude of bipolar square wave initial pulse is 300 V pp for phased array and 400 V pp for conventional channels. High stability of the amplitude and shape of the initial pulse, boosting of all it’s leading and falling edges, and electronic damping are provided by the special circuit significantly improving signal to noise ratio and resolution. Thus analogue gain for each modality is controllable over 0…100 dB range Large 800X600 pixels 8.5” bright screen provides fine resolution for all types of inspection data presentation

Contact Advanced NDT Limited for further information & prices

Click here for more information on ISonic 2009 – UPA Scope Phased Array Flaw Detector

Detector, PA, Ultrasonic, flaw, phased array Product code: ISONIC 2009 UPA SCOPE
View Product
Sold by:

Advanced NDT Ltd.

0.0
Rated 0 out of 5
Website Visit Profile
01905 371 460 Unit 4, Elgar Business Centre Moseley Road, Hallow Worcester Worcestershire WR2 6NJ
NDT Products & Equipment & Pages by Advanced NDT Ltd.

NDT Products & Equipment & Pages

Advanced NDT Limited offer a wide range of (NDT) Non Destructive Testing products including Ultrasonic Thickness Gauges, Coating Thickness …
Engineering
Labino En-Liten White Light add on by Advanced NDT Ltd.

Labino En-Liten White Light add on

Labino EN-LITEN – White Light Add on  Product Code: EN-LITEN EnLiten – White LED After …
Engineering
ISonic AUT 16/32 Multi Channel Flaw Detector by Advanced NDT Ltd.

ISonic AUT 16/32 Multi Channel Flaw Detector

ISonic AUT 16/32 – Multi Channel Flaw Detector  Product Code: ISonic AUT 16/32 Multi Channel …
Engineering
Labino UVG UVG4-HEAD & UVG5-HEAD by Advanced NDT Ltd.

Labino UVG UVG4-HEAD & UVG5-HEAD

Labino UVG Headmounted UV LED Torches   Product Code: Labino UVG4-HEAD & UVG5-HEAD The Labino …
Engineering
Trade Pages
Shopping cart0
There are no products in the cart!
Continue shopping
0